Products » Network Analysers » UPM315



UPM315
UPM315
DIN 96x96 LCD power meter connectable to MFC150 Rogowski coil

Highlights
  • DIN 96 for new or retrofit panels
  • Highly sofisticated power meter providing advanced
  • functionality features
  • Large graphic LCD display with excellent visibility
  • Up to two plug-in options
  • THD even, odd and individual FFT harmonic analysis up to 50th order
  • Power and current demand calculation
  • On-board memory up to 2 MB
  • Programmable Min/Max & energy data logging
  • Event and alarm recording, waveform capture, waveform display, phasor diagrams, historical trending, time-of-use and more...

The UPM315 with option "RGW" can be combined to the MFC150 Rogowski coil.
Applications
  • Switchboards, gensets, motor control centers, etc.
  • Power monitoring & control systems
  • Individual machine load monitoring
  • Power demand analysis and management
  • Harmonics monitoring
  • Remote metering and cost allocation
Main features
Measurements
  • Single-phase and three-phase 3-wire or 4-wire unbalanced load operation.
  • Direct measurement up to 600 (750) VAC.
  • Programmable 1A / 5A current full scale.
  • True rms metering provides accurate measurement even for distorted waveform.
  • Fully bidirectional, four-quadrant readings. 10 energy counters are available, the apparent energy is splitted in four counters: import lagging, import leading, export lagging, export leading.
  • Volts, Amps, Power, PF, Frequency, Energy, Min/Max values, Demand, Harmonics, etc. The full version instrument provides more than 600 measured/calculated parameters and shows on the LCD more than 35 graphical pages.
  • Individual & total harmonic distortion for voltage and current up to the 50th order. The harmonic content is represented like even, odd and total.
  • Advanced waveform capture function. The instrument can store, after a trigger, up to 200 waves with a resolution from 16 to 128 samples (depending on the number of waveforms). The trigger can be programmed on a digital output change, on a set point crossing or the capture can be started from the keypad. The stored waweform is downloadable through the communication port.

Modularity
  • Two slots for optional AO plug-in boards (up to no. 4 analog outputs 0-20 or 4-20 mA).
  • The compact DIN96 instrument allows to t the requirements of new installations as well as retro t applications.

Graphics
  • The excellent graphical display performs clear graphical representations allowing an immediate comprehension of the measured parameters. The voltage and current waveforms, the harmonic spectrum and the phasor diagrams are displayed. Moreover 6 measured values can be represented as a graphical trend on the display. The scale of the trend can be selected between 15 min, 1 hour, 1 day and 1 month.

On-board memory
  • 2 MB non-volatile memory for data storage.
  • Programmable start/stop time of recordings.
  • Wraparound or Fill (FIFO/Stack) selectable recording mode.
  • Min/Avg/Max logging every 1, 5, 10, 15, 30, 60 minutes, programmable up to 8 selectable parameters.
  • Total and daily energy consumption recording. The consumption of more than 300 days is recorded.
  • Time-of-Use (TOU) programmable data recording. The TOU function stores the energy consumption in different registers according the programmed time-scheme. A group of 200 registers gives the situation of the previous and current day, and of the previous and current month. This feature is designed to t different tariff structures, according to the number of TOU included in instrument:
    • 5 TOU: it is possible to program up to 120 daily tariff schedules containing up to 5 tariffs and 15 tariff changes. Each schedule can be assigned to the days of the week and months as requested. Up to 20 holidays can be assigned to the lowest tariff. Moreover, the holiday function can be enabled or disabled. A diagnostic algorithm checks and noti es any setup overlapping.
    • 4 TOU: it is possible to program up to 10 daily tariff schedules containing up to 4 tariffs and 8 tariff changes. Each schedule can be assigned to the days of the week and months as requested. Up to 20 holidays can be assigned to the lowest tariff. A diagnostic algorithm checks and noti es any setup overlapping.
  • In case of more than one electricity supplier, it is possible to start from the recorded demand values instead of the daily ones. Each value is recorded with date and time and can be exported for example, in .xls format. This allows to create a exible map that considers the different electricity suppliers. The DMD value is the AVG value (see programmable recordings).
  • Event, alarm and digital outputs ON/OFF recording. The instrument records the status change of 8 programmable set points, the digital outputs ON/OFF and the instrument supply ON/OFF. All the events are integrated by date and time reference.

Communication
  • Both RS232 and RS485 selectable by dip-switches.
  • Selectable MODBUS or A2 ASCII protocol.
  • Communication speed programmable up to 57600 bps.
  • Optional Pro bus interface.

Inputs & outputs
  • Two digital outputs for energy pulsing or for alarm tripping.
  • Up to 4 analog outputs 0-20 or 4-20 mA.
  • On request input for Rogowski coils.

Other
  • Real time clock with battery backup.
  • Calculation of capacitor bank value for PF compensation.
  • No. 1 programmable user page with 6 parameters selected among measured values.
  • Five alphanumeric character password to avoid unauthorized setup access.
  • Downloadable rmware via serial port.

Specifications
Power supply
Rated voltage: 65...250 VAC / 90...250 VDC
on request 19...60 VDC on request
Consumption: 5 VA max

Voltage inputs
Maximum measurable voltage: 600 (750) VAC max L-L
Input impedance: ›1.3 MOhm
Burden: 0.15 VA max per phase
Frequency: 45 - 65 Hz

Current inputs
Rated current (Ib): 1 / 5 programmable
Min / max measurable current: 20 mA / 7A
Maximum overload: 10 A continuous - 100 A for 1 sec
Input impedance: 0.02 Ohm approximately
Burden: 0.5 VA max per phase
Insulation voltage: 150 VAC max between phases
Rogowski input: 200...49995 A on request

Typical accuracy
Voltage: ±0.1% reading ±0.03% full scale
Current: ±0.1% reading ±0.05% full scale
Active power: ±0.5% reading ±0.1% full scale (PF=1)
Power factor: 1% reading (0.5 inductive - 0.8 capacitive)
Active energy: 1% reading (0.5 inductive - 0.8 capacitive)
Frequency: ±0.05% reading ±2 digits from 45 to 65 Hz

Display and operating controls
Display: backlighted graphic LCD display, 160 x 144 dots
Keypad: 5 push-buttons

Data memory
Type: on-board non-volatile FLASH, 2 MB

Communication port
Type: 1 selectable RS232 or RS485, optoisolated
Baud Rate: programmable from 300 to 57600 bps
Protocols: A2 ASCII, MODBUS

Real time clock
Type: with battery backup
Accuracy: ± 30 ppm

Digital outputs
Type: 2 optoisolated (50V - 300 mADC)

Environmental conditions
Operating temperature: from -15 °C to +60 °C
Storage temperature: from -25 °C to +75 °C
Relative humidity: 80% max without condensation

Mehcanical characteristics
Material: metal enclosure
Protection degree: IP54 (front panel); IP20 (terminals)
Terminals: EU standard pluggable terminals
Size / weight: 96x96x130 mm / 750 g

Standards compliance
Safety: 73/23/EEC and 93/68/EEC directives, EN 61010.1 safety standard
EMC: 89/366/EEC directive and following modifications
93/31/EEC and 93/68/EEC, EN50081-2, EN50082-2, EN61326/A1

Related products

MFC150Rogowski coils
DEDALO DEDALO Software
wintool wintool Software
wintool CT Catalogue

ENTER


and review

<

TECHNICAL AND
PRODUCT NEWS



AREA DEMO

Register or, if you already
have credentials, please
login and enter directly.


ENTER | REGISTER


Client Protected Area

Register for access
or login if you already have
the credentials.


LOGIN | REGISTER



YouTube Channel

YouTube Channel

TECH SUPPORT
& RMA FORM

 

ENTER