Products » Mid Energy Meter » UEM1P5



UEM1P5
UEM1P5, UEM1P5-4D R, UEM1P5-D M, UEM1P5-4D E,
6A three phase energy counter with built-in communication, available interfaces:


Highlights
  • UEM1P5-4D R for RS485 Modbus RTU/ASCII communication
  • UEM1P5-D M for M-Bus communication
  • UEM1P5-4D E for Ethernet (Modbus TCP) communication
  • For 1 or 5A CT
  • Programmable CT ratio
  • Fully bi-directional four quadrants measurements for all energies and powers
  • For 3 / 4 wire networks with balanced or unbalanced load (UEM1P5-4D R and UEM1P5-4D E only for 4 wire networks)
  • Class B according to EN 50470-3
  • S0 output for energy pulse emission
  • Available with MID certification
Applications
  • Totalization of the electric energy in the industry for each single line or machine.
  • Measurement of energy generated by renewable sources such as solar, eolic, etc.
  • Accounting and billing of consumptions in camp sites, malls, residential areas, naval ports, etc.
  • Totalization of the electric consumption in hotels, congress centers, exhibition fairs.
  • Accounting of the consumptions in buildings with executive office services.
  • Internal allocation of the consumptions in timeshare civilian and industrial buildings.
  • Realization of energy monitoring systems.
  • Remote survey of the consumptions and compute of the costs.
Technical features
Power supply
  • Power supplied from the voltage circuit
  • Nominal measurement voltage ±20%
  • Max consumption (for each phase):
    UEM1P5-4D R, UEM1P5-4D E: 3,5 VA - 1 W
  • UEM1P5-D M: 7,5 VA - 0,5 W
  • CT burden (for each phase): 0,04 VA
  • Nominal frequency: 50/60 Hz

Voltage range & frequency
  • Range:
    3x230/400...3x240/415 V 50/60 Hz

Current
  • Starting current Ist: 2 mA
  • Minimum current Imin: 10 mA
  • Transitional current Itr: 50 mA
  • Reference current Iref (In): 1 A
  • Maximum current Imax: 6 A

RS485 Modbus communication
  • Port: RS485
  • Protocol: Modbus RTU/ASCII
  • Communication speed: 300 ... 57600

M-Bus communication
  • Port: wired (EN 1434-3)
  • Protocol: M-Bus
  • Communication speed: 300 ... 38400 bps
  • Unit load: 1

Ethernet communication
  • Port: 10/100 Base T
  • Protocol: HTTP, NTP, DHCP, Modbus TCP
  • Communication speed: 10/100 Mbps
  • Data recording
  • Web server

Accuracy
  • Active energy class B according to EN 50470-3
  • Reactive energy class 2 according to IEC/EN 62053-

S0 output
  • Passive optoisolated
  • Maximum values: 27 VDC - 27 mA
  • Pulse length: 50 ±

Tariff input (no ETHERNET model)
  • Active optoisolated
  • Voltage range for tariff 2: 80 ... 276 VAC-DC

Metrological LED
  • Meter constant: 10000 imp/kWh
  • Pulse length: 10 ±2ms

Environmental conditions
  • Operating temperature: -25 °C ... +55 °C
  • Storage temperature: -25 °C ... +75 °C
  • Humidity: 80% max without condensation
  • Protection degree: IP51 frontal part -IP20 terminals
Related products

Communication Modules
Modbus Master software (for Windows OS)
Communication Modules
M-Bus Master software (for Windows OS)

ENTER


and review

<

TECHNICAL AND