Communication modules
To be combined with UEC1P5 and UEC80 series

Highlights
  • Compact size (1-2 DIN modules)
  • Easy to use: no physical connection thanks to optical port to be combined with the energy counter
  • Possibility to switch the use of the communication module according to the required application
  • Modules: KNX, M-Bus, RS485 Modbus, LAN Gateway
Modules

Compact communication modules suitable for managing energy counters in industrial and civilian application. Thanks to the optical port, the communication with energy counters is quick and easy. All modules can be combined with the following counters:
6A three phase
80A three phase
80A single phase

RS485 MODBUS
RS485 module allows to collect and transmit measurements data of the connected meter to a remote station. This data is transmitted on a RS485 line, using MODBUS RTU or ASCII protocols. MODBUS is the most popular communication protocol designed to allow industrial equipment to communicate. RS485 module is provided with a SET DEFAULT key to reset all communication parameters to factory default values. This function is very useful, i.e. in case of MODBUS logical address forgotten. Two LEDs on the RS485 module provide information about power supply status and communication status.

MBUS
M-Bus module allows to collect and transmit measurements data of the connected meter to a remote station using M-Bus protocol. M-Bus (Meter-Bus) is a European standard for the remote reading of consumption meters. A free dedicated software is provided for module configuration and for displaying the detected measurements.

LAN GATEWAY
LAN Gateway module allows to manage a single energy counter by any PC connected to Internet/LAN by means of a simple web browser. LAN Gateway module web pages are designed to be cross browser compliant: Internet Explorer, Mozilla Firefox, Apple Safari, Google Chrome, Opera, Netscape navigator are all supported web browsers. Another supported feature is MODBUS TCP protocol. MODBUS TCP is the most popular communication protocol designed to allow industrial equipment to communicate over a network. The use of MODBUS TCP provides a totally scaleable solution according to the needs. LAN Gateway module is provided with a SET DEFAULT key to reset all communication parameters to factory default values. This function is very useful, i.e. in case of IP address forgotten. Two LEDs on LAN Gateway module provide information about link activity and status.

KNX
KNX module is a domotic solution for energy counter management to optimise the energy saving. KNX is the worldwide standard for home and building control with a single, manufacturer independent design and commissioning tool (ETS). A single twisted-pair (TP) cable is used for energy counter connection, easy and inexpensive to install: no hub or switch is needed between devices.
Related products

UEC80-4X -3X UEC80-4X
UEC1P5-4X -3X UEC1P5-4X
UEC1P5-X UEC1P5-X
UEC80-X UEC80-X
UEC80-2X UEC80-2X

ENTER


and review

<

TECHNICAL AND
PRODUCT NEWS



AREA DEMO

Register or, if you already
have credentials, please
login and enter directly.


ENTER | REGISTER


Client Protected Area

Register for access
or login if you already have
the credentials.


LOGIN | REGISTER



YouTube Channel

YouTube Channel

TECH SUPPORT
& RMA FORM

 

ENTER